E5270B Precision IV Analyzer/8 Slot Precision Measurement Mainframe
Key Features & Specifications
Current-voltage measurement capabilities
- Accurate and precision measurement ranges of 0.1 fA – 1A and 0.5 µV – 200 V
- Spot and sweep measurement capabilities
- Pulse spot and sweep measurement with minimum 500 µs pulse width
- The ASU (atto-sense and switch unit) can be used with the HRSMU to provide 0.1 fA measurement resolution and SMU/AUX path switching
EasyEXPERT group+ software
- Characterization environment is available on user’s PC
- Intuitive GUI based operation with keyboard and mouse operation
- Multiple measurement modes for quick setup and measurement execution (application test, classic test, and quick test)
- Graphical display, automated analysis capabilities and data generation to Excel and image for analysis and reporting
E5270B hardware
- Configurable and upgradable measurement modules up to 8 slots
- High Resolution SMU (HRSMU), Medium Power SMU (MPSMU) and High Power SMU (HPSMU) are available for configurable SMU selection. Optional ASU is supported for HRSMU.
- High-resolution and high-speed analog-to-digital converters (ADCs) are available to all installed modules
- Active ground unit (GNDU) in mainframe to force 0 V and sink the current up to 4 A
Description
Keysight E5270B Precision IV Analyzer is the complete solution for current-voltage characterization of a wide range of materials and devices. The E5270B supports multiple SMUs (Source/Monitor Units) for voltage/current sourcing and voltage/current measurement with the best in the class current measurement performance as low as 0.1 fA. Its modular architecture allows you to configure or upgrade SMU modules for available eight slots. The EasyEXPERT group+ GUI based characterization software is furnished and available on your PC to support all the tasks required in the characterization from the measurement setup to the data analysis. Powerful integration of SMU’s versatile measurement capabilities and GUI based characterization software makes the E5270B the best solution for characterization and evaluation of devices, materials, semiconductors, active/passive components, or virtually any other type of electronic device with uncompromised measurement reliability and efficiency.
Keysight EasyEXPERT group+ supports efficient and repeatable device characterization in the entire characterization process from measurement setup and execution to analysis and data management either by interactive manual operation or automation across a wafer in conjunction with a semiautomatic wafer prober. EasyEXPERT group+ makes it easy to perform current-voltage characterization immediately with the ready-to-use measurements (application tests) furnished, and allows you the option of storing test condition and measurement data automatically after each measurement in a unique built-in database (workspace), ensuring that valuable information is not lost and that measurements can be repeated at a later date. Keysight E5270B provides the complete solution for current-voltage characterization with these versatile capabilities.
In addition to using as an analyzer, the E5270B is available as a system component SMU for a rack and stuck test system. It provides the scalability and the highest measurement accuracy in the class for current-voltage measurement. It can be controlled remotely by the FLEX command set supporting the powerful measurement capabilities.
Related Software Products
Related Products & Solutions
Documents Library
The parametric Measurement Handbook, Rev 4 This 2018, Rev 4 handbook describes how to evaluate accurate current, voltage, or capacitance measurement by explaining parametric measurement basic Brochure2018-01-08 | |
B1542A Pulsed IV Package User’s Guide Covers operation, installation, and reference information of Pulsed IV Package for B1500A/EasyEXPERT. User Manual2017-02-28 | |
Benefit from Dramatic Improvements with a Transition from the 4155/4156 Analyzer Series This technical overview introduces benefits of a transition from the 4155/4156 analyzer series to the most up to date analyzers. Technical Overview2016-03-08 | |
Precision Current-Voltage Analyzer Series – Technical Overview This literature is a technical overview to provide the brief information of precision current-voltage analyzer series, key features and specification, and differentiations. Technical Overview2016-02-05 | |
E5270B Precision IV Analyzer/8 Slot Precision Measurement Mainframe – Data Sheet This literature provides key features and specifications for the E5270B Precision IV Analyzer / 8 Slot Precision Measurement Mainframe for current-voltage characterization. Data Sheet2016-01-25 | |
Precision Current-Voltage Analyzer Series – Selection Guide The Precision Current-Voltage Analyzer Series ensures accurate and efficient current-voltage measurements that give a clear insight into IV characteristics across a wide range of applications. Selection Guide2016-01-21 | |
E5260A/E5262A/E5263A/E5270B Precision IV Analyzer – Technical Overview This technical overview introduces how to evaluate precision current-voltage characteristics using E5260A/E5262A/E5263A/E5270B Precision IV Analyzer series. Technical Overview2016-01-21 | |
Sheet Resistance/Resistivity Measurement Using a Source/Measurement Unit (SMU) – Application Note This application note provides the technical information for the sheet resistance measurement using the precision current-voltage analyzer series. Application Note2016-01-14 | |
Quick Start Guide for E5260/E5270 Series A step-by-step guide to understand an overview of the E5260 series and the E5270B Precision IV analyzer and setup files used in it. Quick Start Guide2015-10-30 | |
E5260/E5270 Parametric Measurement Solution User’s Guide User’s Guide for E5270B/E5260A/E5262A/E5263A User Manual2015-09-01 | |
E5260/E5270 Precision IV Analyzer Configuration and Connection Guide This configuration guide will help you determine which modules, options and accessories to include with your E5260/E5270, and will also explain detailed connection with examples. Configuration Guide2015-07-06 | |
E5260/E5270 Parametric Measurement Solution VXIplug&play Driver User’s Guide VXIplug&play Driver User’s Guide for E5270B/E5260A/E5262A/E5263A Programming and Syntax Guide2014-10-31 | |
E5270B Parametric Measurement Solution TIS User’s Guide TIS user’s guide for E5270B Programming and Syntax Guide2014-10-31 | |
E5260/E5270 Parametric Measurement Solution Programming Guide Pogramming Guide for E5270B/E5260A/E5262A/E5263A Programming and Syntax Guide2014-10-31 | |
16442B User Guide Provides installation information, operation, maintenance information, and specification of the 16442B Test Fixture for B1500A, B2900 Series, and E5260/E5270 Series. User Manual2014-08-15 | |
Top 5 Reasons to Use Keysight Precision SMU Products for Solar Cell Evaluation Keysight Parameter & Device Analyzers can improve the yields and efficiencies of your solar cells. Promotional Materials2009-08-05 | ![]() |
High Speed Modeling System with IC-CAP Keysight has new modeling system configurations that meet the needs of advanced semiconductor processes. Application Note2008-08-21 | |
Technical Overview :Technique for Controlling Keysight External DC Power Supply Technique for Controlling Keysight External DC Power Supply From SMU to expand SMU output power capability. Application Note2006-08-01 | |
16495C/D/E/F/G/H/J Connector Plate Installation Guide Provides installation information of 16495 Connector Plate. Installation Manual2005-07-01 | |
High Speed L-I-V Test of Laser Diode Using Keysight E5272A/E5273A AN E5270-4 This application note introduces a technique of programming for high speed L-I-V test of Laser Diode in production. Application Note2003-10-17 | |
Evaluation of High Voltage Characteristics of Semiconductor Processes and Devices to 400V AN E5270-3 This application note introduces a technique for expanding the output voltage using the SMU of the Keysight E5270A 8-slot Parametric Measuremnet Mainframe. Application Note2003-10-06 | |
E5270B Parametric Measurement Solution Quick Reference A 2-page quick reference guide to using the E5270B from the front panel. Quick Start Guide2003-10-01 | |
Accurate High Power Device Evaluation to 4 Amperes Using Keysight E5270A AN E5270-1 This application note provides information how to obtain accurate results up to 4A using the E5270A and added flexible modules. Application Note2003-09-19 | |
Tips for Reusing Existing 4142B Program for Keysight E5270A Parametric Measurement Mainframe The purpose of this technical overview is to provide an example of a systematic approach for finding non-operative 4142B program modules or lines in the E5270A instrument,,, Application Note2003-05-10 |